    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    Ask Lasest Price
    Brand Name : XL
    Model Number : XL-500-S WAVE
    Certification : SGS
    Price : $1.2-2/square meters
    Payment Terms : Western Union, T/T, MoneyGram, D/P, D/A, L/C
    Supply Ability : 1000m2/per pay
    Delivery Time : 10 working days
    MOQ : 10 square meters
    • Product Details
    • Company Profile

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    Cooling Tower Fill Media Corrugated PVC Film Fill 500mm Infill Sheet


    Description:


    With cooling towers, fill selection is a critical aspect in this regard. High efficiency film fill may seem the most desirable option. However, if poor water quality causes this fill to rapidly foul and plug, it may incur excessive maintenance costs.

    Most cooling towers now utilize film fill to enhance air/water contact. Film fill, as the name implies, induces the cooling water to form a film on the material surface. The filming mechanism maximizes liquid surface area. A guiding principle behind fill design and selection “is to increase air-to-water contact, driving up convection and evaporative cooling while reducing pressure drop in the system”

    CF500mm cross fluted fills typically provide high specific surface area and high thermal performance but exhibit poor anti-fouling characteristics due to the geometry that forces many deviations to the flow path.
    Flute spacing significantly affects fill performance; smaller spacing increases the surface area but also raises the potentialseverity of fouling.

    Specifications:
    ItemMaterialSheet Size(mm)

    Thickness

    (mm)

    Sheet Space

    (mm)

    Color
    S wavePP, PVC500*1000

    0.3-0.38

    33white, blue, green, black
    500*200033
    CF1900PP, PVC

    305*305*1220/1830

    2440

    0.28-0.3819white, black
    CF1200PP, PVC300*300*1220/1830/24400.28-0.3812/15white, black
    VF1220-MAPP, PVC600*1220, 1220*20000.28-0.3820white, black
    OF21PP, PVC610*458*1220/1830/24400.28-0.3821white, black
    CF-1300PVC1300*3000,1300*30800.28-0.3820black
    CF-1330PVC1330*2500,1330*30000.28-0.3820black
    CF-915-MAPVC915*1854,1220*3000, 1520*30800.28-0.3819black

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mmCorrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm


    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    Related Cooling Tower Film Fill

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    *This type is a film fill system designed for counterflow towers offering you several distinct advantages.
    Crossed corrugations provide the surface area and turbulence to develop efficient heat transfer. The corrugations inherently establish uniform fill sheet spacing at 0.75.

    *Using MC75 film fill in place of existing splash type fill in counterflow towers usually means reduced fill height, which translates into reduced pumping head. MC75 will also provide greater cooling tower capacity, which means your current performance level will require less fan energy.

    *The fill pack depth(air travel) is variable to provide the proper heat transfer area within a single fill layer. If another layer of fill is necessary for situations where additional air travel is required, it will be limited to only one. Limiting the number of interfaces between packs minimizes restrictions that usually cause fill clogging. MC75 counterflow fill can be hung from structural members or it can be bottom-supported in virtually all counter-flow cooling towers, regardless of a cooling tower's age or manufacturer.

    PACKING AND DELIVERY

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm


    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm


    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    About US

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm


    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm


    Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm

    Q: Are you trading company or manufacturer ?
    A: We are manufacturer with our own factory.


    Q: How long is your delivery time?
    A: Generally it is 5-10 days if the goods are in stock. Or it is 15-20 days if the goods are not in stock, it is according to quantity.


    Q: Do you provide samples ? is it free or extra ?
    A: Yes, we could offer the sample for free charge. And the freight cost will on the buyer's side.


    Q: What is your terms of payment ?
    A: Payment<=USD1000, 100% in advance. Payment>=USD1000, 30% T/T in advance ,balance before shipment.

    Quality Corrugated Cooling Tower Fill Media PVC Film Fill 500mm Height 33mm for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuxi Xianglong Plastic Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)